Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Organ Transplantation ; (12): 593-598, 2021.
Article in Chinese | WPRIM | ID: wpr-911689

ABSTRACT

Objective:To explore the predictive values of tissue inhibitor of metalloproteinase-2 (TIMP-2) and insulin-like growth factor binding protein 7 (IGFBP7) in donor sera and lavage fluid on delayed graft function (DGF) in donation after circulatory death (DCD) kidney transplant recipients.Methods:A total of 33 eligible kidney donors and 33 corresponding recipients were recruited. Preoperative serum and renal perfusion fluid samples of donors were collected to determine the levels of TIMP-2 and IGFBP7. Patients were grouped according to whether DGF occurred after kidney transplantation and measured indicators analyzed. Independent sample t test was utilized for comparing the groups with normal distribution measurement data. And χ2 test was employed for comparing the groups with normal distribution counting data and Mann-Whitney test for comparing the groups with non-normal distribution measurement data. Receiver operating characteristic (ROC) curve and area under curve (AUC) were used for evaluating the diagnostic efficacy of indicators. Results:In donor-DGF group, lavage fluid TIMP-2, product of lavage fluid TIMP-2 and IGFBP7 (TIMP-2×IGFBP7), serum IGFBP7 and product of serum TIMP-2 and IGFBP7 (TIMP-2×IGFBP7) were higher than those in donor-non-DGF group ( P<0.05). The AUC of TIMP-2, TIMP-2×IGFBP7, serum IGFBP7 and serum TIMP-2×IGFBP7 in the diagnosis of DGF were 0.753 (95%CI 0.546~0.959), 0.747 (95%CI 0.510~0.984), 0.824 (95%CI 0.615~1.000) and 0.852 (95%CI 0.660~1.000) respectively. Conclusions:Donor serum IGFBP7, donor serum TIMP-2×IGFBP7, lavage fluid TIMP-2 and lavage fluid TIMP-2×IGFBP7 may be used for predicting the occurrence of early DGF after kidney transplantation. Among them, serum TIMP-2×IGFBP7 has the highest diagnostic efficiency and may be an excellent predictor of DGF occurrence.

2.
Chinese Journal of Urology ; (12): 620-626, 2021.
Article in Chinese | WPRIM | ID: wpr-911082

ABSTRACT

Objective:This study is to investigate the predictive value of serum levels of TIMP-2 and insulin-like growth factor-binding protein 7(IGFBP7) in patients with DCD(donation after cardiac death) kidney transplantation.Methods:A prospective research design was used to select DCD kidney transplant patients admitted to the Li Huili Hospital of Ningbo University from January 2018 to October 2020.Inclusion criteria: ①Complete data; ②There were no serious complications affecting the function of the transplanted kidney in the early postoperative period.Exclusion criteria: ①Incomplete data; ②Patients were unable or unwilling to cooperate with the study; ③Severe complications affecting the function of the transplanted kidney occurred early after the operation.The ELASE method was used to quantitatively detect the serum TIMP-2 and IGFBP7 levels at 6, 12, 24, 48, 72 hours and 7 days after renal transplantation, and monitor the serum creatinine values during the same period and 21 days after the operation. According to the occurrence of DGF, the measured values of TIMP-2 and IGFBP7 at different time points and their product's ability to predict the occurrence of DGF after kidney transplantation were analyzed. The receiver operating characteristic (ROC) curve and area under the curve (AUC) were used to evaluate the diagnostic efficacy of TIMP-2 and IGFBP7 for DGF.Results:A total of 33 patients were enrolled, 7 patients (21.2%) in the DGF group and 26 patients (78.8%) in the non-DGF group. Between the two groups, the donor glomerular filtration rate were [98.5(15.8-132.5)ml/(min·1.73m 2) and 79.1(60.6-102.5)ml/(min·1.73m 2)], recipient gender (male/female: 3/4 cases and 10/16 cases), recipient age [48(34-56) Years old and 45(23-61) years old], the recipient's preoperative creatinine [1114.0(731.4-1293.0)μmol/L and 858.4(657.6-1051.9)μmol/L], the recipient's preoperative urea nitrogen [15.0(13.2-19.6)mmol/L and 17.3(13.6-20.9)mmol/L], receptor preoperative albumin [43.5(38.5-45.3)mmol/L and 41.2(37.5-46.1) mmol/L], recipient dialysis method [hemodialysis/peritoneal dialysis: 3/4 cases and 9/17 cases], warm ischemia time [6(5-7) and 5(4-6) min, there was no statistically significant difference] ( P>0.05). The values of serum IGFBP7 and TIMP-2×IGFBP7 in the DGF group were higher than those in the non-DGF group at all time points ( F=15.753, P=0.040; F=13.000, P=0.024), while serum TIMP-2 was not significant between the two groups difference ( F=1.157, P=0.075). For the diagnostic value of DGF, the AUC of serum IGFBP7 at 48 h after surgery was 0.863 (95% CI 0.696-1.000, P=0.004). When 5.97 ng/ml was used as the cut-off value, the sensitivity was 85.7% and the specificity was 80.8 %. The AUC of TIMP-2×IGFBP7 at 48 hours after surgery was 0.819 (95% CI 0.641-0.996, P=0.011). When 62.06(ng/ml) 2 was used as the cutoff value, the sensitivity was 71.4% and the specificity was 80.8%.There was no statistical difference in the area under the curve between the two ( P>0.05). There were differences in the dynamic trend of serum IGFBP7 and creatinine in the DGF group. Serum IGFBP7 at 7 days after surgery was positively correlated with creatinine at 21 days after surgery. Conclusion:Serum IGFBP7 and TIMP-2×IGFBP7 could predict the occurrence of DGF after DCD donor kidney surgery. The predictive value changes with time. Among them, 48h and 7d after surgery are the most valuable. However, serum TIMP-2 has not been found to have predictive value in this study.

3.
Chinese Journal of Postgraduates of Medicine ; (36): 289-291, 2019.
Article in Chinese | WPRIM | ID: wpr-753259

ABSTRACT

Objective To examine arteriovenous fistula (AVF) for hemodialysis by CT angiography(CTA).Methods Sixty-nine patients with chronic renal failure were enrolled in this study. CTA was undertaken by 256-slice scanner. A total of 100 ml of iohexol was administered at a rate of 3 ml/s into a vein of contralateral limb or external jugular vein.Imaging commenced after a delay of 25-30 s and 86 times imaging were performed. Results The AVF were clearly displayed on CTA. Eight CTA were normal. Twenty-five CTA showed stoma stenosis. Forty-two CTA showed venous stenosis. Ten CTA showed stoma stenosis combined with venous stenosis. Only one CTA showed artery stenosis. Conclusions CTA can reveal the AVF safely and correctly,which might help to find abnormality of AVF and direct treatment .

SELECTION OF CITATIONS
SEARCH DETAIL